Products/Services Used | Details | Operation |
---|---|---|
Molecular Biology Reagents> | … at 25 °C, 300 mM KCl, 50 mM (NH4)2SO4, 25 mM MgCl2, and 0.2 % BSA), 1 μl dNTP mix, 1 μl (0.5 unit) Taq polymerase (GenScript), 15.4 μl … Multiplex semi-nested RT-PCR with exogenous internal control for simultaneous detection of bovine coronavirus and group A rotavirus … | Get A Quote |
Commercial kits to determine RNA concentrations are expensive, and sometimes too expensive for laboratories working with tight budgets, especially those in developing countries. We developed, tested, and evaluated two home-made two-step reverse transcription-quantitative polymerase chain reaction assays aimed to detect rotavirus in surface water samples. A commercial one-step master kit was used for comparison. Our results indicated that the efficiency of the home-made assays was comparable to the commercial kit. Furthermore, the lowest detection limit of all assays corresponded to 10⁻⁰·² TCID₅₀ (50 % tissue Culture Infective Dose) per ml. The home-made assays were able to detect rotavirus concentrati... More